Troubleshoot setup

Start at the last checkpoint that succeeded. Keep the complete launch command and its terminal output. For a specific symptom, the FEMU Manual's troubleshooting FAQ answers common questions with links to the issues they came from. Run host checks on the machine running QEMU and guest checks inside the VM; their kernels, devices, and permissions are different.

QEMU does not start​

First check host architecture and KVM access. From the FEMU checkout root on the x86-64 Linux host, verify the binary and the KVM device available to your current user:

test -x build-femu/qemu-system-x86_64
ls -l /dev/kvm
test -r /dev/kvm && test -w /dev/kvm

Inspect each exit status. A missing binary means the build checkpoint was not reached. A missing or inaccessible KVM device needs host configuration before the documented -enable-kvm launch can work. Do not infer guest compatibility from a successful standalone NAND test.

For a property or geometry error, retain the exact QEMU message, source commit, INI file, and expanded arguments. Compare them with the complete recipe and compatibility rules. Configuration expansion alone does not validate device realization. If startup reports memory allocation or pinning trouble, follow host resource planning.

A warning such as femu: serial has no effect and is accepted only for compatibility does not stop QEMU. serial, ms, ms_max, dlfeat, tplpbsy, tplrbsy, trcbsy, nr_thread, time_slice and context_switch_time are accepted so old command lines still start, but nothing reads them; remove them from the launch line. Identify Controller reports a serial number FEMU generates, not the serial value.

QEMU runs but the terminal stays blank​

Confirm that the boot image path is correct and the image is bootable with the launcher's machine, firmware, and virtio disk attachment. -nographic does not configure the guest's console. Check the guest kernel command line and serial login setup in The guest image.

Kernel messages without a login prompt point to a different checkpoint from no kernel output. Keep that distinction in a report. Do not troubleshoot FEMU namespace commands until the guest has booted and you can run them.

The guest boots but the expected device is missing​

Inside the guest, collect:

uname -r
lsblk -o NAME,TYPE,SIZE,MODEL,MOUNTPOINTS
sudo nvme list
sudo dmesg | tail -n 100

If installed, lspci -nnk can distinguish PCI controller presence from driver binding. Compare its controller and driver information with the boot log. Verify that the running QEMU command includes the intended FEMU device and namespace configuration. Another NVMe device may own /dev/nvme0.

Controller presence does not guarantee an ordinary block namespace. In particular, use the KV probe for KV mode. For block modes, check the selected controller with nvme id-ctrl and its namespace with nvme id-ns, as shown in the quick start.

Commands work but the result differs​

Keep command exit status, returned data, state transitions, and performance measurements separate. An unsupported command or missing placement directive needs interface investigation; unexpected timing needs configuration and counter interpretation. For example, a GC-policy change can have no effect when the workload never reaches collection.

Use the recipe report outline to report the last successful checkpoint and the first failed command. Include errors as text and remove private paths, credentials, and workload data before sharing. These steps organize diagnosis; the full guest setup still requires validation on your Linux/KVM host.